PME-C160 |
|
|
|
|
|
Tel:+86-510-83591868 Email:sales@pinnaclemachines.com |
|
|
|
|
|
Description |
Technical Data |
Maintenance |
|
|
Reversible Plate Compactor
Forwarder and reversible plate compactor with centrifugal force of 24-38KN can cope with extreme demands as the reverse action allows better manoeuvrability in small spaces. The compactors are smooth motion and easy to operate. Excellent for road works,foundations,backfill in pipe trenches and pipeline construction, in landscaping as well as in paving.
Advantage of compaction
Compaction is defined as the method of mechanically increasing the density of Foundations. In construction, this is a significant part of the building process. If performed improperly, settlement of the soil could occur and result in unnecessary maintenance costs or structure failure. Almost all types of building sites and construction projects utilize mechanical compaction techniques.
In compaction constructions,your equipment reliability becomes essential to the success or failure of each project. PME has covered with a full offering of construction equipment for many types of construction jobs. The right machine can prevent various structural problems such as cracking and leaking walls, foundation erosion, slab issues and breakage in pipes, and improve construction quality.PME can supply you complete construction solutions. We’re here whenever you need us.
Features:
Comfortable operation
Heavy duty shock buffer mounts to reduce vibration toward upper deck and handle.
The throttle lever intergrated in the steering arm and the ergonomic design of the travel control lever gives optimum control of the plate at all times.
Safety and reliability
The large size engine frame gives outstanding protection against damage.
External cage to protect the plate from accidental damage.
The V-belt drive is fully enclosed for better safety and trouble free use.
More efficiency
Infinitely variable centrifugal force, infinitely variable forward and reverse speed and stationary vibration for maximum flexibility on a wide range of soil conditions.
More utilisation
Adjust working widths with interchangeable extension plate.
Properly curved edges for easy access to corners during compaction.
|
Model
|
PME-C160H
|
PME-C160L
|
PME-C160R
|
PME-C160BS
|
Engine
|
Honda GX270
|
Loncin G270F
|
Robin EY28
|
B&S 306
|
Engine type
|
Air-cooled,single cylinder,4-stroke,petrol engine
|
Displacement [cc]
|
270
|
270
|
273
|
306
|
Engine power [HP]
|
9.0
|
9.0
|
7.5
|
10
|
Rated power [KW]
|
5.1
|
5.4
|
5.6
|
7.5
|
Speed [RPM]
|
3600
|
3600
|
3600
|
3600
|
Starting system
|
Manual start
|
Employed fuel
|
93#
|
Employed oil
|
10W-30
|
Fuel tank capacity [L]
|
6
|
6
|
5.5
|
5.3
|
Oil tank capacity [L]
|
1.1
|
0.95
|
0.85
|
1.1
|
Frequency [VPM]
|
4500
|
Centrifugal force [KN]
|
30
|
Plate size (L x W ) [cm]
|
70x50
|
Max. compaction depth [cm]
|
60
|
Travel speed [m/min]
|
20
|
Efficiency [m2/h]
|
500
|
Max. inclination angle
|
20º
|
N.W./G.W. [kg]
|
170/185
|
Package (L x W x H) [cm]
|
84x54x104
|
|
Engine Periodic Maintenance Schedule
|
REGULAR SERVICE PERIOD
|
Each use
|
First month or 20 Hrs.
|
Every 3 months or 50 Hrs.
|
Every 6 months or
100 Hrs.
|
Every year or 300 Hrs.
|
Performed at every indicated month or
operating hour interval, whichever comes first.
|
ITEM
|
|
Engine oil
|
Check level
|
√
|
|
|
|
|
Change
|
|
√
|
|
√
|
|
Air cleaner
|
Check
|
√
|
|
|
|
|
Clean
|
|
|
√(1)
|
|
|
Replace
|
|
|
|
|
√☆
|
Sediment Cup
|
Clean
|
|
|
|
√
|
|
Spark plug
|
Check-Clean
|
|
|
|
√
|
|
Replace
|
|
|
|
|
√
|
Idle speed
|
Check-Adjust
|
|
|
|
|
√(2)
|
Valve clearance
|
Check-Adjust
|
|
|
|
|
√(2)
|
Fuel tank and strainer
|
Clean
|
|
|
|
|
√(2)
|
Combustion chamber
|
Clean
|
After every 300 Hrs. (2)
|
Fuel line
|
Check
|
Every 2 years (Replace if necessary) (2)
|
☆ Replace the paper element type only.
(1)Service more frequently when used in dusty areas.
(2)These items should be serviced by your servicing dealer unless you have the proper tools and are mechanically proficient. Refer to manual for service procedures.
Plate compactor Periodic Maintenance Schedule
|
Time/contents
|
Daily Before Starting
|
After First 5 Hrs.
|
After First 50 Hrs.
|
Every Week or 25 Hrs.
|
Every month or 100 Hrs.
|
Every 3 months or 300 Hrs.
|
Check fule level
|
√
|
|
|
|
|
|
Check oil level of machine
|
√
|
|
|
|
|
|
Check fule line and fittings for cracks or leaks
|
√
|
|
|
|
|
|
Tighten Bottom plate hardware
|
|
√
|
|
√
|
|
|
Check and tighten engine cylinder screws
|
|
√
|
|
√
|
|
|
Check and tighten external hardware
|
|
√
|
|
√
|
|
|
Check V-belt
|
|
|
|
|
√
|
|
Function of Controlling System
|
√
|
|
|
|
|
|
Battery Check
|
|
|
|
|
√
|
|
Clean engine cooling fins
|
|
|
|
√
|
|
|
Clean recoil starter
|
|
|
|
|
|
√
|
Change vibrator oil
|
|
|
√
|
|
|
√
|
Clean engine muffler and exhaust port
|
|
|
|
|
|
√
|
Note: If engine performance is poor,please check,clean and replace air filter elements as needed.
|
|
|
Leave Message |
|
Please feel free to leave your inquiry in the form below.
We will reply you in 24 hours. |
|
|