6KW diesel generator
PME always develops products against the customers request. The 6KW diesel generator is a gap in the market. This generator is power by PME192F(E), which can run continuously at 6KW full power.
Feature
Convenient maintenance
Large service doors provide easy access to preventive maintenance and service checks.
Low running noise
High efficiency combustion system ensures complete combustion. A large silencer dampens exhaust noise and engine sound are contained in a double wall structure and absorbed.
Alternator winding
Waveform distortion is kept at a minimum level with a stable output. The winding design protect the generator from short circuit and provide a stable output while running inductive loads.
Low oil alarm system
Before the oil level drops to a dangerous level, the generator will stop automatically. It can be restarted after the proper oil level is restored.
ATS as optional
The automatic transfer switch can be applied to dual voltage, single phase and three phase generator sets. When utility power fails, a automatic transfer switch senses the loss of power and immediately starts the generator. Once utility power is restored, the transfer switch shifts your electric load back to utility power and shuts off the generator.
Digital control panel as optional
All control functions of the generator are on a central panel. A digital display indicates the real time performance data of the generator, such as voltage, frequency, oil pressure and battery condition.
|
|
Model
|
PME8000SE
|
Alternator
|
Rated frequency [Hz]
|
50/60
|
Rated power [kw]
|
6.0kw (50Hz); 6.2kw (60Hz)
|
Max.power [kw]
|
6.4kw (50Hz); 6.7kw (60Hz)
|
Rated voltage [v]
|
115/230;120/240; 220/380 (depend on requirement)
|
Power factor
|
1.0 or 0.8
|
Phase
|
Single phase or three phase
|
Engine
|
Mode
|
PME192FE
|
|
Type
|
Single-cylinder, vertical, air-cooled, 4-stroke, diesel engine
|
|
Starting system
|
Electric start
|
Genset
|
Fuel tank capacity [L]
|
16
|
Continuous running time [h]
|
7.5h (50Hz); 6.3h (60Hz)
|
Noise(7m) dB(A)
|
72
|
N.W/G.W
|
180/188
|
Package (L x W x H) [cm]
|
111.5x75x84.5
|
|
Periodic Maintenance Schedule
|
REGULAR SERVICE PERIOD
|
Each use
|
1st month or 20 Hrs.
|
Every 3 month or 100 Hrs.
|
Every 6 month or 500 Hrs.
|
Every year or 1000 Hrs.
|
Performed at every indicated month or operating hour interval, whichever comes first.
|
Check and fill fuel
|
√
|
|
|
|
|
Discharge fuel
|
|
√
|
|
|
|
Check and fill oil
|
√
|
|
|
|
|
Check oil leakage
|
√
|
|
|
|
|
Check and tighten externa hardware
|
√
|
|
|
|
|
Change oil
|
|
√
|
√
|
|
|
Change oil filter
|
|
|
|
√
|
|
Change air filter element
|
|
|
|
√(1)
|
|
Clean filter of Fuel
|
|
|
|
√
|
√(2)(change)
|
Check high pressure oil pump
|
|
|
|
√(2)
|
|
Check nozzle
|
|
|
|
√(2)
|
|
Check fuel pipe
|
|
|
|
√(2)
|
|
Adjust gaps of air intake and exhausted gate
|
|
√(2)
|
|
√(2)
|
|
Grind air intake and air exhausted gate
|
|
|
|
|
√(2)
|
Change piston ring
|
|
|
|
|
√(2)
|
Check electrolytic solution of accumulator
|
Each month
|
Check electric brush and slide ring
|
|
|
|
√(2)
|
|
Check insulation resistance
|
Stop working is over 10 days
|
(1)Service more frequently when used in dusty areas.
(2)These items should be serviced by your servicing dealer unless you have the proper tools and are mechanically proficient. Refer to manual for service procedures.
|
|
|